You want the mower off the kitchen floor, or a pond pump off an open window, and the title says the socket will do both, plus a hot tub. An outdoor socket for a lawn mower can be a normal 13 A face on a 30 mA supply. A hot tub, a second heavy tool, or a pond you swim in is a different job. This page is from the Products Compared editorial team on 21 October 2026. The faces are the eleven rows in the [garden sockets comparison](/hub/sockets-and-extension-leads/garden-sockets). Figures are that day’s amazon.co.uk capture, not a lab test. A qualifying purchase can earn a commission at no extra cost to you.

You want the mower off the kitchen floor, or a pond pump off an open window, and the title says the socket will do both, plus a hot tub. An outdoor socket for a lawn mower can be a normal 13 A face on a 30 mA supply.

Our top picks

RICOKEY RICOKEY IP66 double

Best value

RICOKEY RICOKEY IP66 double
9.7/10about £12.98
LIKEEM LIKEEM IP66 double, 3 m

Alternative

LIKEEM LIKEEM IP66 double, 3 m
8.6/10about £18.99
On this page

A mower is a 13 A plug, not a new kind of socket

A mains mower with a BS 1363 plug needs a 13 A outlet on a 30 mA supply. Electrical Safety First says use an RCD with outdoor tools, and do not mow grass that is wet with dew. LIKEEM reviews describe one mower or one pressure washer on the 3 m twin, lead uncoiled, into a socket that already trips at 30 mA. Read the mower’s plate. Place the box off the cutting path and shut the lid when you wheel the mower away. The buying order is on the outdoor socket buying guide.

A pond pump is a product standard, not an IP sticker

A small mains pond pump can use one of these faces when the pump meets BS EN 60335-2-41 and the cable follows the maker’s instructions. That standard belongs to the pump, not to an IP66 sticker. Electrical Safety First wants a reputable pump, an RCD tested at least every three months, and a protected cable. Add the wattages. On a pre-wired kit they share one 13 A plug. A pump plus a mower does not. A pond you bathe in falls under section 702, the swimming-pool rules, not a garden socket. Fitting stops are on how to fit an outdoor socket.

Two sockets on one lead are still one fuse

On every pre-wired kit both sides are the same 13 A plug. LIKEEM states overload protection in the plug, not a fuse per outlet. Kukkasilta prints a 13 A fuse and up to 3000 W. At a nominal 230 V, 13 A is 2,990 W. A printed 3250 W beside 13 A and 250 V is the listing’s figure, not permission for two motors at once. A pressure washer is a tool you run and then unplug, on an RCD, with the lead uncoiled. If you need the mower and the washer the same afternoon, run one, then the other.

A hot-tub line is not a rating

Kukkasilta’s highlight names hot tubs and pool pumps. The bullets say up to 3000 W and a 13 A fuse, and they do not say an RCD. One review says a 13 A hot tub melted the socket. Another says a hot tub was fine. Do not average those into a rating. IP66 does not raise the fuse. If a socket has melted, switch off, unplug if you can do that safely, and get a registered electrician. Do not fit a larger fuse. A mower, one pressure washer, or a pond pump with a small UV, on a 30 mA supply, lid shut and box off the cutting path, is the job these faces support.

Common questions

Can I plug a mower into one of these sockets?
Yes, if the mower has a UK 13 A plug, the socket is for outdoor use, and a 30 mA device protects the supply. Use one tool at a time on a plug-in kit, uncoil the lead, and do not mow wet grass. Electrical Safety First is the source for the RCD and the dew warning. Keep the box off the mower’s path.
Can the same box run a pond pump all year?
A small pump that meets BS EN 60335-2-41 can, if you follow the maker’s cable instructions and test the 30 mA device at least every three months. A lead in the border all year is a weak version of that. A hard-wired outlet is the more settled feed. If the pump fails, switch off and use a registered electrician.
Can I run the mower and the pump together?
Not on a pre-wired kit. Both outlets share one 13 A fuse. A pump plus a small UV can fit if the plates stay inside that plug. A mower plus a pump does not. Two switches only isolate the faces. They are not two fuses.
Is a pressure washer the same kind of load?
It is a 13 A tool you run and then unplug, on an RCD, lead uncoiled. Zenmos reviews include a jet washer. It is not a second tool beside the mower, and it is not a reason to hose the socket. IP66 assumes a closed enclosure. IP44 will not take a jet.
Why do listings mention hot tubs?
A bullet can name a duty the fuse does not support. Kukkasilta names hot tubs and also prints a 13 A fuse and up to 3000 W, with no RCD. One review says a tub melted the socket. Another says a tub was fine. Treat the line as advertising. Kent Traders keeps hot tubs off a general outdoor socket.
Does IP66 mean I can hose the socket?
No. IP66 is dust-tight and protected against powerful jets in a stated test, with the enclosure closed. It is not immersion and not a jet-wash of an open face. One lucky review is not a test. The orange inline connector is only IP44.
Where should the box sit so the mower does not hit it?
Off the cutting line, so the deck and the cable do not meet. One article suggests at least 30 cm above the ground. That is advice, not a BS 7671 height. Shut the lid after use. A cracked lid is no longer the enclosure that was rated.

Related pages

Sources

Sources taken from the research digest. Listings were scored on 21 October 2026. This page did not run a lab test.

  1. IET Wiring Matters — 30 mA RCD for socket-outlets (retrieved 21.10.2026)
  2. Electrical Safety First — wiring regulations help (retrieved 21.10.2026)
  3. NICEIC — gardens and electrics (retrieved 21.10.2026)
  4. Approved Document P — electrical safety in dwellings (retrieved 21.10.2026)
  5. Northern Connectors — what IP44 means (retrieved 21.10.2026)
  6. Clarion — IP ratings, including IP66 (retrieved 21.10.2026)
  7. Electrical Safety First — extension leads and cable reels (retrieved 21.10.2026)