Independent comparisons. We may earn from shop links. More info

Kopp socket buying guide UK: series, IP and plugs

Updated: 23 October 2026

A garage, a workshop or an older back box needs an outlet, and you want to know whether a Kopp listing will take the plug on your bench. This Kopp socket buying guide UK is that check, before you spend about £2.85 or £18.31. The seven outlets in our [Kopp sockets comparison](/hub/sockets-and-extension-leads/kopp-sockets) are continental protective-contact sockets, 16 A at 250 V on amazon.co.uk, not BS 1363 thirteen-amp wall sockets. A UK three-pin plug will not seat in them. Prices are from 20 October 2026. We did not run a lab test. A qualifying purchase can earn a commission at no extra cost to you.

A garage, a workshop or an older back box needs an outlet, and you want to know whether a Kopp listing will take the plug on your bench.

Our top picks

On this page

Who these Kopp sockets are for

These boxes suit a circuit that already uses continental outlets: a workshop, a garage, an outbuilding, a caravan, or a property wired that way. Regulation 35 of the Electrical Equipment (Safety) Regulations 2016 is about the appliance plug suiting a BS 1363 socket. Fixed wiring still follows BS 7671. The 16 A figure is the nominal current of the outlet.

Nautic, Paris, and the standard programme

Nautic is the lidded surface range: grey vertical double about £8.30, switch and single about £4.77, white horizontal double about £2.85, anthracite listing about £5.67. The first three state IP44. The white horizontal does not describe the terminals. The anthracite title says an economy pack, one bullet says a 10 A switch, and the item type says a 16 A double. Buy it only after the photo matches. Detail is on the Kopp Nautic IP44 socket page. Paris is flush and IP20. Model 923502087 is about £4.08 and the frame is a separate order. Model 920702011 is about £18.31, about £3.05 an insert, and does not say whether frames are included. That page is the Kopp Paris flush socket guide. The standard double, model 102502002, is about £5.26, screw terminals, no lid, no IP rating, rigid conductors only. Follow the earth-contact title, not the 2-pin bullet.

IP ratings and the room

IP20 on Paris is indoor protection. A bathroom in the six-pack bullets does not raise that field. IP44 on Nautic is splash protection, the usual reading of those digits in BS EN 60529, including solid objects larger than 1 mm where the bullet says so. A surface-waterproof line on the white double is stronger than the IP44 field. A utility or a garage bench under a roof matches the listing text. An open patio needs a higher IP on the plug system you actually use. CE on a specification line is not building-control sign-off.

Wiring, plugs, and when to stop

Where Nautic bullets mention terminals, they describe a removable interior and a plug-in terminal up to 2.5 mm². The vertical double and the anthracite listing have no factory link in the reviews, so you add link wires. Paris reviewers describe screwless terminals and soft fixing screws. The standard double is screws and rigid conductors only. None of these is a trailing socket. If you cannot see how the circuit is protected, use a registered electrician. Our guide to installing Kopp sockets is the point where you down tools. Part P differs across England, Wales, Scotland and Northern Ireland.

Common questions

Will my normal UK plug fit these Kopp sockets?
No. These are continental protective-contact outlets, 16 A at 250 V, not BS 1363 thirteen-amp sockets. A UK three-pin plug will not seat in them. Only the single Paris listing names plug types C, E and F. If your appliances use UK plugs, choose a BS 1363 socket rather than an adaptor on one of these boxes.
What is the difference between Nautic and Paris?
Nautic, in this set, is a surface box with a hinged lid and an IP44 line, for cellars, washrooms, garages and workshops as the bullets put it. Paris is a flush insert, IP20, high gloss, and the single tells you the cover frame is a separate order. The standard programme double is a third thing: an indoor surface box with screw terminals and no lid.
When is IP44 enough?
IP44 is splash protection, which suits a damp utility, a workshop, or a socket under a canopy if the rest of the installation is right. It is not a claim of hose-proof or open-rain performance. A bullet that says surface-waterproof does not replace the IP44 field. Unsheltered walls need a higher rating and, usually, a different socket system.
Can I replace a UK double socket with Kopp without an electrician?
Not as a like-for-like swap. The plug, the back box and often the circuit design are different. If you are unsure which standard the property uses, or you need a new circuit or RCD, use a registered electrician. Fixed wiring in the UK is governed by BS 7671, not by the amazon.co.uk title.
What does 16 A mean for my circuit?
It is the nominal current printed on these outlets, at 250 V. It does not mean a continental adaptor can feed a high-power UK appliance as if it were a 13 A British socket. Cable size still has to match the circuit. Where a Nautic bullet states a limit, it is conductors up to 2.5 mm².
Are the Amazon reviews from UK fitters?
The star totals are the amazon.co.uk counts. The written samples in our files are mostly from Germany, with some from the Netherlands, France, Sweden, Spain, Belgium and Italy. Treat them as comments on the plastic, the lid and the terminals, not as evidence of how the box sits on a UK back box.
Is CE marking enough for building control?
No. CE on a listing, where it is printed, is not a substitute for the pin layout, the current, the IP rating, or whether your insurer and the building rules accept the work. The standard double does not print a CE line in our file. Confirm the installation with someone who can sign off fixed wiring.

Related pages

Sources

Sources taken from the research digest. Listings were scored on 20 October 2026. This page did not run a lab test.

  1. Heinrich Kopp GmbH product catalogue (retrieved 20.10.2026)
  2. BSI — BS 1363 plugs and socket-outlets (retrieved 20.10.2026)
  3. Electrical Equipment (Safety) Regulations 2016, regulation 35 (retrieved 20.10.2026)
  4. Plugs and Sockets etc. (Safety) Regulations 1994 (retrieved 20.10.2026)
  5. IET Wiring Regulations (BS 7671) (retrieved 20.10.2026)
  6. IEC 60529 degrees of protection (IP code) (retrieved 20.10.2026)