Door closer buying guide

Updated: October 2026

You have a door that will not stay shut, and the amazon.co.uk door closers list has already mixed three different machines into one scroll. This door closer buying guide is the order to use before you compare brands: name the job, pick the mechanism that can do it, then read the power size and the paperwork. Shelf prices in the set behind our [door closer comparison](/hub/door-and-window-security/door-closer) ran from about £7.99 to about £49.90 on 19 October 2026. Peter F. used those listings and public UK guidance, not a lab test. A purchase through our links can earn a commission at no extra cost to you.

You have a door that will not stay shut, and the amazon.co.uk door closers list has already mixed three different machines into one scroll.

Our top picks

On this page

Three closers, three jobs

An overhead hydraulic closer is a body on the frame and an arm on the door. Oil checks the travel, and a second valve, when the listing has one, sets the latch. A surface spring, including Burg-Wächter and Offfay, the best value for a light door, only stores coil tension. A stick-on cable, the about £7.99 pair, has pads and no tension adjuster in the reviews. A drifting bedroom door can live with a spring in the about £8 to £13 band. A slamming kitchen door needs the valves. A flat entrance does not start in the spring row. The fork is on hydraulic door closer vs spring.

Power size, not the title

BS EN 1154 size 3 is about 950 mm and a 60 kg test door. Size 4 is about 1,100 mm and an 80 kg test door. If width and mass disagree, take the higher size. Sizes 1 and 2 are not the fire or smoke grade. One listing pairs about 750–850 mm with 25–45 kg, which is not that 60 kg test door. Another says size 3 and then quotes two masses plus up to 1,100 mm. A 1,050 mm kitchen door takes size 4. The comparison’s top pick, the Carlisle, at least states one size. Models come after measuring, on the best overhead door closer page.

What to read on the listing

A printed classification is a six-digit EN 1154 code: power size, and fire behaviour grade 0 or 1. Certifire is a scheme name. A fire-door bullet is not that code. We did not fire-test any unit. Do not read ADA or UL text as UK approval. In England, many flat entrance doors are checked under the Fire Safety (England) Regulations 2022 guidance on GOV.UK. Scotland, Wales and Northern Ireland run their own arrangements. On 19 October 2026 springs and cables were about £8 to £13, and the dearest overhead kit was about £49.90. A fire door belongs on the fire door closer page.

Force, mount, and fixings

Where Approved Document M volume 2 applies, opening force is limited to 30 N from 0° to 30° and 22.5 N from 30° to 60°. Do not wind a closer until people prop the leaf. In a house those figures are not the legal test, but a closer a child cannot open is still wrong. Fig. 1 is the pull-side mount. A parallel arm is the push-side arrangement. A template matters because a body fitted upside down is not a valve fault. This guide does not crown a model.

Common questions

What size door closer do I need for a normal internal door?
Measure the width and make an honest guess at the mass. A leaf around 950 mm and up to the 60 kg test mass is the size 3 point in the EN 1154 table. A narrower, lighter bedroom door often works with a smaller closer or a spring, though a spring will not give two-speed control. If the door is wider than 950 mm, move up a size even if it feels light. Size 3 is the usual start for a standard internal fire door, not for every cupboard.
Is size 3 enough for a fire door?
Size 3 is the minimum power the trade guidance treats as the fire-door grade, and sizes 1 and 2 are not. Enough still depends on the actual leaf. If the door is wider than about 950 mm or heavier than the 60 kg test mass, you take the higher size. The closer also needs fire-behaviour evidence for that door, not only the words size 3 in a title. A spring labelled size 3 is not the same object.
What does the six-digit EN 1154 code mean?
It is the classification string for a controlled door closer. The digits cover the category of use, endurance, door mass and size, fire behaviour, safety, and corrosion resistance. Fire behaviour is grade 0 or grade 1. You use the code to see whether the closer was classified for the size and the fire job you have, and you still match it to the leaf in front of you. A bullet that merely says EN 1154 has not shown you those digits.
Can I use a spring closer on a kitchen door?
You can, if the kitchen door is a light internal door and it is not a fire door. A spring in the about £8 to £13 band will pull it shut, and you set tension rather than two hydraulic speeds. It is a poor choice when the door slams on the latch, because more tension usually makes that worse. If the kitchen door is the fire door to an integral garage or a flat entrance, a spring is the wrong type. Use a controlled closer and the fire-door checks.
Will the same closer fit a uPVC front door?
Only if the listing says the fixings and the mount suit that frame, and only if the door is allowed to carry a closer. One kit in this set states screws for metal, wood and PVC. Most of the cheap springs do not. A uPVC front door is often a fire-escape or security door with its own closer specification, and a stick-on cable will not do that job. Check the door maker’s limits before you drill the frame.

Related pages

Sources

Public UK guidance and trade sources from the research digest, used for this page in October 2026. Prices, stars and review counts are the amazon.co.uk figures dated 19 October 2026. A listing claim of EN 1154 or Certifire is not treated as a certificate for your door.

  1. GOV.UK: Fire Safety (England) Regulations 2022, fire door guidance (retrieved 19 October 2026)
  2. Approved Document M, volume 2 (2024 amendments) (retrieved 19 October 2026)
  3. Code of Practice: hardware for fire and escape doors (retrieved 19 October 2026)
  4. Hoppe: BS EN 1154 (retrieved 19 October 2026)
  5. GAI door closer safety checklist (retrieved 19 October 2026)
  6. Fire Protection Association: do fire doors need to be self-closing? (retrieved 19 October 2026)
  7. Intertek: EN 1154 (retrieved 19 October 2026)
  8. MB Direct: how to adjust the speed of a door closer (retrieved 19 October 2026)