Independent comparisons. We may earn from shop links. More info

Plasma cutter duty cycle: what the percentage means

DiagnosisOctober 20267 min read
Inverter plasma cutter cooling on a bench between cuts in a UK garage

A plasma cutter duty cycle is the share of ten minutes at a stated current. See why 35% and a bare 60% on these UK listings differ without a stated current.

Top pick: Reboot CUT60
Top pick: Reboot CUT60
See comparison →

You are halfway along a 3 mm bracket, the inverter case is already warm, and the listing you ordered from showed either 35% or 60%. A plasma cutter duty cycle answers that only when two numbers travel together: a percentage, and the current it belongs to. The percentage is the share of a ten-minute period the power source may spend cutting at that stated current. In the eleven amazon.co.uk listings in our plasma cutter comparison, only the Reboot CUT60 attaches 35% to its 60 A description. The SUSEMSE LT55 prints "60% high-duty circle" and names no amps. The other nine pages print nothing, and nothing is not a licence to cut all afternoon.

In short

A plasma cutter duty cycle is a fraction of ten minutes at a named current. Thirty-five percent is three and a half minutes of cutting in that window, and only at the current printed beside it. Sixty percent is six minutes, and only when the listing actually states the current. Where this set prints neither number together, treat the duty cycle as n/a and plan short cuts with a cool-down, rather than a continuous run at the headline amp.

What a plasma cutter duty cycle is counting

The useful reading is a clock, not a quality score. Take the ten minutes as the whole window. At 35%, the arc-on allowance is three and a half minutes, and the rest of the ten minutes is there for the power source to cool. At 60%, the arc-on allowance is six minutes. That arithmetic follows from the definition. It is not a stopwatch test of any machine in this set, and it collapses the moment the current is missing.

The current is the part people skip. A 35% rating at 30 A and a 35% rating at 60 A are different thermal jobs, because the inverter is shedding different amounts of heat. A 60% line with no amps beside it does not tell you whether those six minutes were claimed at 20 A, at 40 A, or at the biggest number in the title. You can still buy the cutter. You cannot turn the percentage into a working timetable.

The two figures these listings print

Eleven inverter air plasma cutters sit in the comparison file, from Reboot, SPRIGHOLLY, PLASMARGON, Haxiaoer and SUSEMSE, with shelf prices from £67.83 to £199.00 on amazon.co.uk. They are not Stahlwerk machines. Duty cycle is printed on two of the eleven pages.

The Reboot CUT60, ASIN B0DTG34CST, is the clear one. The listing price in this file is £132.04, with 4.6 from 28 reviews. A bullet puts a 12 mm clean cut, a 16 mm maximum and a 35% duty cycle on the 60 A description. Technical details say 240 V. The page does not print a plug rating. If you take the bullet as written, 35% at that 60 A description is three and a half minutes of arc in each ten-minute window, at that current.

The SUSEMSE LT55, ASIN B0C61S56PB, is the unclear one. The listing price is £99.99, with 4.1 from 34 reviews. The title says 55 A. A bullet says "60% high-duty circle". No current is attached to that percentage. Planning six minutes at 55 A from that phrase would invent the missing half of the spec.

The other nine pages leave the duty-cycle line empty: the SPRIGHOLLY CUT50L, CUT60 and CUT60L PRO, the Reboot 45 A, the Reboot non-HF 40 A, the PLASMARGON CUT55, PLC65 and CUT65 Pro, and the Haxiaoer HXC600D. The CUT50L, ASIN B0GKDNVWPD, at £67.83, does not print one. The missing percentage is still a missing percentage, on the cheap machine and on the £199 non-HF machine alike.

A review that says 60 percent

One UK review of the Reboot CUT60 states a 60% duty cycle. Keep that sentence in the review column. The bullet on the same product says 35%, attached to the 60 A description. Averaging them to something near 47% would describe no document you can point at. Use 35% at the 60 A description as the listing claim. When the machine arrives, the label and the manual outrank both.

Why a 13 amp machine prints a lower current

A BS 1363 plug with a 13 A fuse is rated at 13 A. That is the input side, at the wall. The 40 A, 50 A, 55 A and 60 A numbers on these titles are output claims at the torch. They are not the current the fuse is carrying. These listings do not print the input current next to the duty cycle, so you cannot finish the sum from the product page alone.

R-Tech's P32D shows what a complete line looks like on a different machine. That page publishes 35% at 30 A, a lower output so the input can stay at 13 A, with an 8 mm clean cut and 12 mm severance. Those are R-Tech's figures for R-Tech's cutter. Copying "35% at 30 A" onto the Reboot, the SUSEMSE, or the SPRIGHOLLY CUT50L would invent a spec their amazon.co.uk pages do not carry.

A long SPRIGHOLLY review, in the research behind this comparison, says these inverters are often happy near half the headline current on a 13 A plug, and that full headline current needs a higher-rated supply. Treat that as the reviewer's rule of thumb, not as a British Standard and not as a result we measured. Half of a 60 A title is 30 A. One verified review of the Reboot CUT60 says a 13 A fuse blew. Plugs and fuses are covered in the guide to a plasma cutter on a 13 amp supply. Anything beyond a standard 13 A socket is an electrician's job.

What to do when the cutter stops

Stop the arc and leave any thermal cut-out exactly as the maker fitted it. Bridging a sensor or holding the trigger through a trip turns a pause into a burnt inverter or a damaged torch. Unplug the machine and give it the remainder of that ten-minute window at least. Waiting six minutes and striking again at the same headline amp, on the same long extension, repeats the condition that stopped you.

Every cutter in this set needs an outside compressor, and no box includes one. The CUT50L bullet asks for 90 PSI and 60 L/min. The Reboot CUT60 lists 30–70 psi. The SUSEMSE lists 0.35–0.5 MPa, which the page also gives as 50–70 psi. A dry or starving torch can stop a cut and can overheat a tip. It is a different diagnosis from "the percentage was too low".

After a cool case and a restored air supply, a cutter that strikes again was behaving like a limited duty cycle or a supply limit. A cutter that will not hold an arc, or that fails again after a short spell of normal use, is a fault. The Consumer Rights Act 2015 gives you 30 days to reject goods that are faulty. Leave the fuse at the rating the plug and the circuit were built for.

How to read the next listing

Read the duty line as a pair before you compare prices. First, is there a percentage at all? Second, is a current in the same claim? A page that passes only the first test, as the SUSEMSE does, is unfinished. A page that passes both, as the Reboot CUT60 bullet does, can be turned into minutes with the ten-minute sum. A page that fails the first test gets n/a written next to it. Nine of these eleven fail that test.

The Reboot's 35% does not transfer to the CUT50L. The SUSEMSE's 60% does not transfer to a PLASMARGON title. R-Tech's 35% at 30 A does not transfer to any of these ASINs. Silence is allowed. Filling silence with a neighbour's number is how a buying note becomes a false spec.

Prices and review counts above are the amazon.co.uk shelf figures stored for this comparison in October 2026. Products Compared read the eleven listings, including bullets, technical details and the review lines those files contain, and used R-Tech's published 35% at 30 A on the P32D as a separate UK example. We did not cut metal in a lab, and we did not invent duty cycles for the nine pages that omit one. Links to amazon.co.uk use the tag pcuk26-21. A qualifying purchase can earn a commission at no extra cost to you.

Common questions

What does a plasma cutter duty cycle mean?
A plasma cutter duty cycle is the share of a ten-minute period the power source may cut at a stated current before it needs to cool. Thirty-five percent is three and a half minutes of arc in those ten minutes, at the current printed beside the percentage. Sixty percent is six minutes, and only when a current is printed too. The percentage on its own is incomplete. The amazon.co.uk pages in this set do not attach a lab test to the figure, so the bullet is the seller's claim.
Is 60% better than 35% on a plasma cutter?
A higher percentage is a longer share of the ten minutes only when both figures sit next to the same current. In this set they do not. The Reboot CUT60 listing prints 35% on its 60 A description, at £132.04. The SUSEMSE LT55 prints "60% high-duty circle" and names no amps, at £99.99, even though the title says 55 A. You cannot rank those two lines. A review that says 60% on the Reboot stays a review and does not replace the 35% bullet.
Can I cut for six minutes in every ten?
Six minutes in every ten is what 60% means, at the current the listing states. The SUSEMSE bullet does not state that current, so six minutes at 55 A is not a plan you can take from those words. The Reboot CUT60 bullet is 35%, which is three and a half minutes in ten at the 60 A description. None of the eleven listings prints 100%. A 4T latch keeps the trigger on without your hand clenched. It still counts as arc time inside the same window.
Why did the plasma cutter get hot and stop?
Heat in the inverter rises with current and with how long the arc stays on. Near a headline amp on a UK 13 A plug, a stop can be the duty-cycle limit, a thermal cut-out, or a fuse. Leave the cut-out in place, unplug, and let the case cool before you try again. Confirm the compressor is still delivering the air the listing prints, because none of these boxes includes one. If the torch will not restart after a proper cool-down, stop striking it.
Does 4T change the duty cycle?
4T latches the arc so a long cut does not depend on a clenched hand. 2T runs the arc only while you hold the trigger. Neither mode adds amps, and neither lengthens the share of the ten-minute window. A latched cut is still arc time. Where a SPRIGHOLLY bullet allows 2 to 15 seconds of post-flow air after the arc, that air is a cool-down. It is not a duty-cycle percentage, and those pages still leave the duty-cycle field empty.
Is the duty cycle the same at every amp?
A duty cycle belongs to the current printed beside it. Less current usually leaves more thermal room, but these listings do not print a second percentage, so there is nothing further to look up. A long SPRIGHOLLY review offers a rule of thumb: these inverters are often happy near half the headline current on a 13 A plug, and full headline current needs a higher-rated supply. That applies the reviewer's rule as arithmetic. It is not a standard and not a test of your machine.
Why do trade machines print a lower current?
A UK 13 A fuse is rated at 13 A. Torch amps are a different number from the current at the plug. R-Tech publishes 35% at 30 A for the P32D, a lower output so the input can stay on a 13 A supply. That pair belongs to the P32D. It is not a duty cycle for any ASIN in this amazon.co.uk set, and it should stay off any 50 A or 60 A page that left the field blank. A headline amp with no percentage is an unfinished claim.
Which of these listings print a duty cycle?
Two of the eleven. The Reboot CUT60, ASIN B0DTG34CST, prints 35% duty cycle on the 60 A description. One UK review of that machine states 60%, and that figure stays the review. The SUSEMSE LT55, ASIN B0C61S56PB, prints "60% high-duty circle" with no current attached. The other nine, including the SPRIGHOLLY CUT50L and the Haxiaoer HXC600D, do not print one. Those nine leave the duty cycle unpublished. A neighbour's percentage does not fill the gap.
Peter F.
Products Compared

Products Compared publishes British-English buying guides based on amazon.co.uk listings and public UK sources. We do not run a lab and we do not invent test scores.

Updated: October 2026

Related articles