The box is in the hall, or it is still in the basket, and you want it over the table in the gazebo or on the ceiling indoors. How to mount a ceiling heater starts with the fixing the listing actually describes, then the gap to the floor, then the socket. It ends where a householder should stop. The [ceiling heater comparison](/hub/heating/ceiling-heater) shows what each of the six listings claims. This page does not rank them. If you have not chosen a tube, a panel or a light, that choice is the [ceiling heater buying guide](/hub/heating/ceiling-heater/sub/ceiling-heater-buying-guide). Clearances below are examples from named sources. Your model’s manual wins if the numbers differ. A qualifying purchase can earn a commission at no extra cost to you.

The box is in the hall, or it is still in the basket, and you want it over the table in the gazebo or on the ceiling indoors.

Our top picks

On this page

Check the mount before you drill

A title that says ceiling is not a fixing plan. On both Hocosyme listings the title says ceiling-mounted and the first bullet describes a suspension cable, while the mounting field says wall. The Wi-Fi highlight says wall and ceiling. If you drill for a cable hang and the manual that arrives is a wall bracket, you have followed the title and ignored the field. Donyer’s mounting field says ceiling, the bullets describe an adjustable chain, and the form-factor field says pedestal. Pro Breeze says ceiling or wall in a bullet, spelled “celling” on the page, and the mounting field says wall. Fixtures are said to be included. One review in that file says the brackets were missing. Open the pack and match the metal to the manual before you are on a ladder with a hole already drilled. The two ceiling lights are screw-in or ceiling-mount lights, not chain-hung tubes. Lpoppcx puts an E27 fitting in the title. One reviewer could not get the lamp body fully onto the holder. A gazebo beam and a plasterboard ceiling are different structures. A hook has to be rated for the weight, with margin. The Heat Outdoors hanging-lamp manual, for that model, asks for a hook rated several times the weight of the heater. Hocosyme’s bullet claims a cable support up to 50 kg, which is the seller’s line, and the two panels print 17.2 kg and 7 kg for the same envelope. Do not hang either until the manual and the weight in your hands agree.

Height and clearance

Use the manual in your box. Publishing one height for a panel and a hanging lamp would mix two products. As an example only, the Heat Outdoors hanging-lamp manual uses at least 1.8 m from the underside of the heater to the floor, at least 0.5 m from the heater to the ceiling, and about 1 m from obstructions. It also says not to open the unit, and it excludes bathrooms. That is that lamp, not a rule you copy onto a Hocosyme panel. Donyer’s bullet suggests a hang of 70.9 inches, about 1.80 m, in the same region as that 1.8 m example. It is still Donyer’s sentence. Pro Breeze does not print an equivalent hang height in the fields stored here. If your ceiling is low, a 1.8 m underside gap may not exist. In that case you do not split the difference. You do not fit that hanging lamp. A gazebo lining, a parasol or a curtain can sit inside the hot zone even when the floor gap looks fine. Halogen tubes glow and run hot. If you cannot find a clearance in the manual, stop. A heater slung so that a tall guest can touch the guard is too low, even if a bullet’s inch figure has been met on paper.

Socket, RCD and the lead

Reviewers of both outdoor heaters call the mains lead short. Pro Breeze states 182 cm. Donyer states 39.37 inches, about a metre. Electrical Safety First says not to run a patio heater from an extension lead. A lead that does not reach the outdoor socket is not a reason to add a reel. Move the socket, or pick a different fixing point the manual allows, or stop. The outdoor socket should be a proper outdoor point, at least IP44 in Electrical Safety First’s patio-heater advice, on a supply that is RCD-protected. An indoor socket just inside the bi-fold, with a lead across the threshold, is the extension-lead problem in another shape. Fitting a new outdoor circuit is an electrician’s job. A 2,000 W load at 230 V is about 8.7 A, so it can sit on a 13 A BS 1363 fuse if the appliance is built for a plug. Donyer’s spec table also prints 14 A. Do not solve that by changing the fuse in the plug. If the manual shows a permanent connection and no plug, do not fit a 13 A plug to the flex. The two outdoor listings are compared on the best ceiling heater page. That page does not replace the manual’s wiring diagram.

When to stop

Stop when the room contains a bath or a shower and the wiring would be new. Part P covers new fixed wiring in a bathroom, including electric ceiling heating in a local-authority note such as Thurrock’s. A registered electrician does that work. Hanging a patio halogen in a wet room is not a workaround. Bathroom zones stay on the bathroom ceiling heater page. The Heat Outdoors manual excludes bathrooms for its lamp, and Electrical Safety First says outdoor patio heaters stay outdoors. Stop when the manual forbids a 13 A plug, when the outdoor socket is missing or has no RCD, or when two 2 kW heaters already trip the circuit. Stop when the switch has melted, the unit has smoked, or a tube has shattered. Donyer reviews include a melted switch and smoke. Pro Breeze reviews include a bulb that could not be replaced. Unplug it, do not open the case, and do not fit a similar tube from a drawer unless the manual names a replaceable lamp and the ratings match. You can mark a joist, hang a chain the pack includes, and plug into an existing protected outdoor socket when the manual says that is the installation. If the paperwork in the box contradicts the amazon.co.uk title, the paperwork is what you mount to.

Common questions

How high should the heater hang?
Follow the manual for that model. As examples only, one Heat Outdoors hanging-lamp manual uses at least 1.8 m from the underside to the floor, and Donyer’s bullet says 70.9 inches, about 1.80 m. Those are not a shared height for a panel and a tube. If your ceiling cannot provide the gap the manual asks for, do not fit that heater.
How far from the ceiling and from fabric?
The same Heat Outdoors manual uses 0.5 m to the ceiling and about 1 m from obstructions. A gazebo fabric or a curtain can be too close even when the floor gap is right. Do not copy those distances onto a different brand if its manual prints other figures. If the manual is silent, stop rather than guessing.
Can I use an extension lead if the flex is short?
No. Electrical Safety First tells you not to feed a patio heater from an extension lead. Pro Breeze’s flex is 182 cm and Donyer’s is 39.37 inches, and reviewers still call both short. Use an existing outdoor socket the lead can reach, or have a socket fitted where the manual allows the heater to hang.
Does a 2,000 W heater belong on a 13 A plug?
Only if that model is supplied for a plug. At 230 V, 2,000 W is about 8.7 A, under a 13 A fuse. A 13 A plug is a poor match for a 3 kW load left running. Do not add a plug to a heater the manual says must be connected permanently.
What does 14 A on the Donyer listing mean for the socket?
The spec line prints 14 A and 220 next to heat steps that top out at 2,000 W. Fourteen amps is more than a BS 1363 13 A fuse, and it does not equal 2,000 W. Do not change the fuse to match the spec line. Follow the manual, and treat a ban on a 13 A plug as an electrician’s decision.
When is this an electrician’s job?
New fixed wiring in a bathroom is notifiable under Part P. So is a new outdoor circuit, a missing RCD on the outdoor supply, a manual that demands a permanent connection, and a board that trips when the heater runs. Checking a chain onto an existing, suitable socket is the householder’s side of the line.

Related pages

Sources

Public UK sources named below. amazon.co.uk prices, stars and review counts on these six listings were taken from the listing files read on 20 October 2026. Page updated October 2026.

  1. Ofgem price cap, 1 October to 31 December 2026 (retrieved 20 October 2026)
  2. SELECT, BS 7671 Section 701 bathroom guide (retrieved 20 October 2026)
  3. NICEIC bathrooms and electrics (retrieved 20 October 2026)
  4. Electrical Safety First patio heaters (retrieved 20 October 2026)
  5. Energy Saving Trust, infrared heating explained (retrieved 20 October 2026)
  6. DESNZ infrared heating review (retrieved 20 October 2026)
  7. Ecostrad Accent IR ceiling panels (retrieved 20 October 2026)
  8. Heat Outdoors hanging-lamp manual (retrieved 20 October 2026)