Meter isolator switch: what sits beside the meter
You are looking at the electricity meter in a UK cupboard and trying to tell the black cut-out from a meter isolator switch you are allowed to use. They sit a few centimetres apart and they do not belong to the same person. The cut-out fuse is the network's. The customer's isolator, if there is one, is on your side of the meter, in the tails that run on towards the consumer unit. This page stays with that boundary and with three 100 A enclosures in the [mains isolation switch comparison](/hub/electrical-equipment/mains-isolation-switch): the WFIS100, the WEC4400 and the WEC440SP. A 13 A plate is the wrong current for this cupboard. There is no lab test.
You are looking at the electricity meter in a UK cupboard and trying to tell the black cut-out from a meter isolator switch you are allowed to use.
You are looking at the electricity meter in a UK cupboard and trying to tell the black cut-out from a meter isolator switch you are allowed to use. They sit a few centimetres apart and they do not belong to the same person. The cut-out fuse is the network's. The customer's isolator, if there is one, is on your side of the meter, in the tails that run on towards the consumer unit. This page stays with that boundary and with three 100 A enclosures in the mains isolation switch comparison: the WFIS100, the WEC4400 and the WEC440SP. A 13 A plate is the wrong current for this cupboard. There is no lab test.
Our top picks
| Badge | Product | Poles | Fuse | Surge protection | Note | Price | Offer |
|---|---|---|---|---|---|---|---|
| Best overall | WCED WCED WEC440SP | 4 pole | Not listed | Type 2 SPD | 9.2 | about £30.00 | View offer |
WCED WCED WEC4400 | 4 pole | No | No | 8.8 | about £22.49 | View offer | |
WCED WCED WFIS100 | Not listed | 80 A and 100 A fuses | No | 8.6 | about £21.00 | View offer |
On this page
The fuse in the cut-out is not your switch
Three 100 A enclosures, three different extras
Tails, length and the cabinet
What has to be in the carton
Common questions
Is the main fuse the isolator?
What is a 100 A switch for?
Fused switch or plain isolator?
Does the SPD enclosure belong in the cupboard?
Why will 25 mm² tails not sit straight?
Is a 4-pole switch for a normal house?
Related pages
Sources
Public UK sources are listed below. Shelf prices and star lines are the amazon.co.uk figures in the product files. Checked October 2026.
- HSE HSR25, Electricity at Work Regulations 1989, regulation 12 (retrieved October 2026)
- HSE, work near electricity (retrieved October 2026)
- Electrical Safety First, Best Practice Guide 2 issue 4.3 (retrieved October 2026)
- IET Wiring Matters, July 2026, Table 537.4 (retrieved October 2026)
- IET extractor-fan FAQ (retrieved October 2026)
- Approved Document P 2013 (retrieved October 2026)
- SI 2012/3119, regulation 12(6A) (retrieved October 2026)
- UK Power Networks, a typical domestic supply (retrieved October 2026)