Bootlace ferrules and BS 7671
A 1,200-piece kit on amazon.co.uk can look as if every stranded cable in a UK house needs a sleeve. That is not what the Wiring Regulations ask. This page is when BS 7671 Regulation 526.9 points at a treated end, and when a bootlace ferrule is the wrong treatment. The pliers sit on the [crimping pliers set comparison](/hub/pliers/crimping-pliers-set). A qualifying purchase can earn us a commission at no extra cost to you. Fine strands need a suitable terminal or a treated end. A crimped ferrule is one treatment. A badly fitted one is worse than bare wire under the same screw.
A 1,200-piece kit on amazon.co.uk can look as if every stranded cable in a UK house needs a sleeve. That is not what the Wiring Regulations ask.
A 1,200-piece kit on amazon.co.uk can look as if every stranded cable in a UK house needs a sleeve. That is not what the Wiring Regulations ask. This page is when BS 7671 Regulation 526.9 points at a treated end, and when a bootlace ferrule is the wrong treatment. The pliers sit on the crimping pliers set comparison. A qualifying purchase can earn us a commission at no extra cost to you. Fine strands need a suitable terminal or a treated end. A crimped ferrule is one treatment. A badly fitted one is worse than bare wire under the same screw.
Our top picks
| Badge | Product | Ferrule range | Jaw | Sleeves | Note | Price | Offer |
|---|---|---|---|---|---|---|---|
| Best overall | Preciva Preciva ferrule crimper set, 1,200 sleeves | 0.25–10 mm² | Square | 1,200 singles | 9.4 | about £22.99 | View offer |
| Alternative | Preciva Preciva ferrule kit with twin sleeves | 0.25–10 mm² | Self-adjusting | 260 dual-tube pieces | 9.4 | about £23.99 | View offer |
| Best value | Hibisaws Hibisaws ferrule kit, 1,250 sleeves | 0.25–10 mm² | Square | 1,250 singles | 9.0 | about £19.99 | View offer |
On this page
What Regulation 526.9 actually asks for
Where a ferrule is the wrong treatment
Twin ferrules and collar colours
What this does not permit
Common questions
Are bootlace ferrules compulsory in a UK house?
Do I ferrule 2.5 mm² twin and earth?
What about a cage clamp or a lever terminal?
Can I put two wires in one ferrule?
Why is the collar colour not red, blue and yellow?
Should I ferrule the meter tails?
Who should do the consumer unit?
Does CE on the pliers mean the crimp meets BS 7671?
Related pages
Sources
Public UK sources from the research digest, last checked on 19 October 2026. Shelf prices and star lines are the amazon.co.uk figures in the display file.
- IET Wiring Matters: Mythbuster 5, terminal blocks and ferrules (retrieved 19 October 2026)
- IET EngX: Ferrule crimps (retrieved 19 October 2026)
- IET EngX: Crimping of flexible cord conductors (retrieved 19 October 2026)
- BSI: BS 7609:1992+A2:2009, uninsulated power connectors (retrieved 19 October 2026)
- HSE: Electricity at Work Regulations guidance, HSR25 (retrieved 19 October 2026)
- RS: Bootlace ferrules (retrieved 19 October 2026)
- RS: Knipex 97 53 04 crimp tool (retrieved 19 October 2026)
- Klauke GB: Insulated solderless terminals (retrieved 19 October 2026)